Raychem self-regulating systems offer the most flexible approach for heat-tracing design. An unconditional T-classification, the possibility to cut the cable to
length on site, the easiest installation are just some highlights which give this technology its unprecedented reputation of flexibility and reliability. Self-regulating systems are mostly used in more complex pipeworks, typical applications are line lengths of up to 250 m and maintain temperatures of up to 150°C.
|

|
 |
|
Raychem power-limiting
systems provide higher power outputs at elevated temperatures than
self-regulating systems and can be exposed to higher temperatures while
maintaining the advantages of cut-to length cables. For line lengths of up to
250 m, for maintain temperatures of up to 230°C.
|

|
 |
|
Isopad and HEW-THERM
polymer insulated (PI) series heating systems are especially suitable for
longer heating circuits (e.g. >250 m) and can be used for exposure
temperatures of up to 300°C. Depending on the application, they typically
require more sophisticated control systems.
|

|
 |
|
Pyrotenax mineral
insulated (MI) series heating systems are recommended for high-temperature
applications of up to 800°C. Various constructions of the heating cables are
offered to best suit the requirements of harshest industrial environments. A
range of components and accessories complete this technology offered by Tyco
Thermal Controls.
|

|
 |
|
Raychem constant-wattage parallel heating systems offer an economical alternative while maintaining the advantages of cut-to length cables. Because of their constant power output, circuit breaker sizes may be reduced compared to self-regulating heating systems. For line lengths of up to 200 m, for maintain temperatures of up to 200°C. Depending on the application, they typically require more sophisticated control systems.
|