Pipe diameter
|
| Insulation thicknesses |
mm inches |
15
½ |
22
¾ |
28
1" |
35
5/4" |
42
1 ½ |
54
2" |
67
2 ½ |
76
3" |
108
4" |
125
5" |
150
6" |
200
8" |
|
| 10 mm |
|
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
|
| 15 mm |
|
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
|
| 20 mm |
|
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
|
| 25 mm |
|
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
|
| 30 mm |
|
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
|
| 40 mm |
|
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
FS-B-2X |
|
| 50 mm |
|
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-A-2X
FlexiClic FP |
FS-B-2X |
FS-B-2X |
FS-B-2X |
Frost protection cables FS-A-2X and FS-B-2X are suitable for any pipe material (copper, threaded pipes, stainless steel pipes, plastic pipes and composite metal pipes without restriction)
For plastic pipes, please use aluminium adhesive tape ATE-180. The frost protection cable should be covered along its entire length. Heat insulation ? = 0.035 W/(m.K) or better.
Important note: frost protection heating cables with fluorpolymer protective jacket (e.g. type BTV2-CT) must be used for solvent containing, mixed and/or bitumen-coated heat insulation.
40°C temperature maintenance on pipelines for fatty waste water
|
|
Pipe diameter
|
|
Insulation thicknesses |
42
1½ |
54
2" |
67
2½ |
76
3" |
108
4" |
125
5" |
150
6" |
200
8"
|
|
30 mm
|
FS-C-2X |
|
|
|
|
|
|
|
|
| 40 mm |
FS-C-2X |
FS-C-2X |
FS-C-2X |
|
|
|
|
|
|
| 50 mm |
FS-C-2X |
FS-C-2X |
FS-C-2X |
FS-C-2X |
|
|
|
|
|
| 60 mm |
FS-C-2X |
FS-C-2X |
FS-C-2X |
FS-C-2X |
FS-C-2X |
FS-C-2X |
FS-C-2X |
FS-C-2X |
|
Min. ambient temperature -10°C. Heat insulation ?= 0.035 W/(m.K) or better.
The FS-C-2X heating cable should only be used for pipework with a minimum continuous temperature resistance of 90°C. A line-sensing control thermostat (type AT-TS-14 or RAYSTAT-CONTROL-10) must be used for plastic pipes (setting approx. 40°C).