| Product Features |
A self-regulating system for concrete surfaces
|
A constant wattage, Mineral Insulated (MI) system for asphalt surfaces
|
|
EM2-XR |
EM2-MI |
|
 |
 |
| Product Description |
Self regulating heating cable |
Mineral insulated constant wattage heating cable |
| Features |
Extremely robust self regulating heating cable for flexible installation under severe. |
Pre-terminated heating cable with exceptional resistance to high temperature asphalt surfaces. |
| Voltage Rating |
230 Vac
|
230 Vac
|
| Nominal power output |
90 W/m @ 0°C.
|
50 W/m
|
| Maximum circuit length |
85 m
|
136 m
|
| C-Type circuit length |
Yes |
Yes |
| Maximum exposure temperature |
100°C
|
250°C
|
| Connection requirements |
Cut-to-length system for flexible field termination (using Raychem heatshrink components). Pre-terminated cable lengths (fixed or configured) available. Contact us |
Factory terminated |
| Compatible control unit |
VIA-DU-20
|
VIA-DU-20
|
| Approvals |
VDE / CE |
VDE / CE |
| Suitable for installation on Reinforcement bar |
• Recommended |
•• Recommended |
| Suitable for installation on without reinforcement |
••
Recommended
|
••
Recommended
|
| Suitable for installation in direct contact with hot poured asphalt |
|
•••
Highly Recommended
|
| Suitable for embedding in sand sub-level |
••
Recommended
|
••
Recommended
|
| Pre-terminated system |
Available upon request |
Yes |
| Cut to length on-site |
Yes |
|
| Cold lead included |
Not as standard. Contact Tyco Thermal Controls for information on configured EM2-XR heating elements. |
Yes - 3 Metres (at each end of heater cable) |
| Dual Wire / Single Wire construction |
Dual |