Pyrotenax System 1850 SE

 
Literature
Installation Operation and Maintenance Manuals
>>Service Entrance Cable Systems- Design Considerations & Installation Guidelines
>>System 1850 SE Installation Highlight
Datasheets
>>System 1850-SE Datasheet
Engineering Specification
>>U.S. CSI Model Specification: Service Entrance System
Sales Brochures
>>Commercial Construction Wiring Brochure
>>System 1850 SE Brochure
Miscellaneous
>>Appendix A: Pyrotenax MI Cable Characteristics
>>Appendix B: Pyrotenax MI Voltage Drop Calculations
>>Appendix C:Pyrotenax MI Temperature Characteristics
>>Appendix D: Pyrotenax MI and Raycehm S-600 Cable Expansion and Vibration
>>Appendix E: Copper Sheathed Cable and Corrosion
>>Appendix F: Copper Sheath Cable - Sheathed Currents
>>Appendix G: Engineering Specs for Tyco Thermal Controls Wiring Systems
>>Appendix L: Pyrotenax MI Sheath Bonding & Grounding
>>Appendix M: Magnesium Oxide Insulation Characteristics
>>UL Fire Test Guidelines Tech Info Sheet
Design Guidelines
>>Service Entrance Cable Systems Design Guide
Installation Instruction
>>SE-Protect Installation Instructions

INSTALLATION TOOLS
Banding ToolsBending ToolsCable Straightener
Crimping Tools (Bulk Wiring Only)Handvise (Bulk Wiring Only)Power Sheath Stripper (Bulk Wiring Only)
Power Stripper Heads (Bulk Wiring Only)Ratchet Type Stripping ToolSheathmaster (Bulk Wiring Only)
WIRING ACCESSORIES
Brass PlatesCable Banding KitsCable Tray
Conductor Sleeving (Bulk Wiring Only)Copper Clips and StrapsHigh Temperature Compound (Bulk Wiring Only)
PVC Shrouds (Bulk Wiring Only)SE Quickterm PyropaksStraight Through Joints (Bulk Wiring Only)

< back

   

Pyrotenax
System 1850 SE

 System 1850 SE
System 1850-SE is a service entrance cabling system that allows service entrance conductors to be routed inside the building. It consists of the following major components:

  • Underwriters Laboratories 2 hour fire resistive mineral insulated cable

  • QuickTerm brand service entrance cable termination kits

  • NEMA Class 12B galvanized steel ventilated cable tray with louvered covers


Advantages of System 1850-SE

When running traditional service entrance conductors through the building, concrete encasement is necessary so the conductors are considered outside the building. With System 1850-SE, concrete encasement is not necessary. System 1850-SE cable has been subjected to the following testing:

  • Mechanical strength, impact and crush

  • Electrical impulse

  • Vibration

  • Fire resistance to 1850°F

  • On-site field service for consultation during the installation

  • Installation completion inspection by company certified technician





 
 
 