Pyrotenax Zero EMI System

 
Literature
Installation Operation and Maintenance Manuals
>>Zero EMI Cable Systems- Design Considerations & Installation Guidelines
Datasheets
>>Zero EMI Datasheet
Sales Brochures
>>Commercial Construction Wiring Brochure
Miscellaneous
>>Appendix B: Pyrotenax MI Voltage Drop Calculations
>>Appendix C:Pyrotenax MI Temperature Characteristics
>>Appendix D: Pyrotenax MI and Raycehm S-600 Cable Expansion and Vibration
>>Appendix E: Copper Sheathed Cable and Corrosion
>>Appendix F: Copper Sheath Cable - Sheathed Currents
>>Appendix G: Engineering Specs for Tyco Thermal Controls Wiring Systems
>>Appendix J: Zero EMI Frequently Asked Questions
>>Appendix L: Pyrotenax MI Sheath Bonding & Grounding
>>Appendix M: Magnesium Oxide Insulation Characteristics
Design Guidelines
>>Zero EMI Cable Systems Design Guide

INSTALLATION TOOLS
Banding ToolsBending ToolsCable Straightener
Crimping Tools (Bulk Wiring Only)Handvise (Bulk Wiring Only)Power Sheath Stripper (Bulk Wiring Only)
Power Stripper Heads (Bulk Wiring Only)Ratchet Type Stripping ToolSheathmaster (Bulk Wiring Only)
WIRING ACCESSORIES
Brass PlatesCable Banding KitsCompensator
Conductor Sleeving (Bulk Wiring Only)Copper Clips and StrapsFactory Splices
High Temperature Compound (Bulk Wiring Only)PVC Shrouds (Bulk Wiring Only)Quickterm Pyropaks (Bulk Wiring Only)
Straight Through Joints (Bulk Wiring Only)

< back

   

Pyrotenax
Zero EMI System

 Zero EMI System
Electro-Magnetic Interference on sensitive data communication equipment and computers in offices, hospitals, computer rooms etc., is increasingly becoming a major concern when electrical feeders are routed above, below or adjacent to rooms containing the equipment.

In many instances, even low levels of interference on important data communication systems are unacceptable.

With the huge increase in the use of computers and DC drives over the last decade has come a corresponding growth in harmonic distortion on power supplies. The impact of the increase in harmonics occurs in two areas - increased heating, often leading to increased sizing of the neutral conductor, and - an exacerbated EMI problem.

Conventional solutions do exist in the form of shielding the circuits with magnetic material - however, usually at great cost. Now, there is a unique solution which utilizes the high ampacity/size, ratio of MI and the patented "Zero EMI" system.

The "Zero EMI" system reduces the magnetic field external to the cable to effectively zero. A patented device, called a compensator, injects current into the sheath of the MI cable exactly equal and opposite to the conductor current, thereby nullifying any external magnetic field and effectively eliminating any possibility of interference.




 
 
 