Pyrotenax MI Cable-Alloy 825

 
Literature
Installation Operation and Maintenance Manuals
>>Industrial Heat-Tracing Installation and Maintenance Manual for Mineral Insulated Cable Systems for Pipes and Vessels
Data Sheets
>>MI Cable-Alloy 825 Datasheet
>>MI Cable-Alloy 825 Datasheet (French)
>>MI Cable-Alloy 825 with PyroFLX Cold Lead Datasheet
Product Design and Selection Guides
>>Design Guide for Mineral Insulated Cables
Specifications
>>Engineering Specification for Electrical Heat-Tracing Systems (Word Format)
Product Overview
>>Longline Product Overview
Sales Brochures
>>Industrial Heating Capabilities Brochure
>>Industrial Heating Capabilities Brochure (French)
Miscellaneous
>>Appendix A: Heat-Tracing Design Request Form
>>Appendix B: Self-Regulating/Power-Limiting Design Worksheet
>>Appendix C: Tank Design Worksheet
>>Appendix D: Tubing Bundle Design Request Form
>>Appendix E: Ground-Fault Equipment Protection Device Selection
>>Appendix F: Classification of Hazardous Locations
>>Appendix G: Hazardous Gases and Vapors
>>Appendix H: Approval for Class I, Division 1 Hazardous Locations in USA
>>Appendix I: Required Installation Record for Class I, Division 1 Hazardous Locations in USA
>>Appendix J: Class I, Division 1 in USA — Frequently Asked Questions
>>Appendix K: Engineering Specification for Electrical Heat-Tracing Systems
>>Appendix L: NEMA Enclosure Types
>>Appendix M: Typical Circuit Breaker Trip Curve
>>Appendix O: Unit Conversion Tables
>>Appendix P: Glossary of Terms
>>Biofuels Heating Flyer
>>MI Cable Sheath Temperature Test Methods and Design Optimization Techniques
>>Product Safety Notice
>>Project Profile – Beijing Airport Automated People Mover (APM) System
>>Project Profile - Complete Heat Management System Turkey Provider
>>Project Profile – Dock Pump and Transfer Line Heat-Tracing System
>>Project Profile – OMV Maari Field
>>Project Profile – Optimization of HMS Using DigiTrace Control & Monitoring Systems
>>Project Profile – Qatargas Sulfur Transfer Line
>>Project Profile – Thermal Energy Storage Tank Insulation System
>>Sulfur Transport Pipelines Brochure
Product Information
>>Industrial Heat Tracing Catalog

CONTROL & MONITORING
Contactors
E104E304 
Electronic Controllers
910920JBS-100-ECP-A
JBS-100-ECW-AT2000 
Mechanical Thermostats
AMC-1AAMC-1BAMC-2B-2
AMC-F5 
HEAT TRACE PANELS
HTPGHTPI 
HEATING ACCESSORIES
Junction Boxes
D1297D1297-TERM3PTJB
RMI-JB3 
Mounting Brackets
D1297-Bracket

< back

   

Pyrotenax
MI Cable-Alloy 825

 MI Cable-Alloy 825
Alloy 825 Mineral Insulated Heating Cables provide solutions for industrial freeze protection and process-temperature maintenance applications in hazardous and non hazardous locations.

MI is also used where high power output, high exposure temperatures, or extreme resistance to environmental corrosives are needed. MI heating cables can provide up to 82 watts per foot (269 watts per meter) of power output with area classification and design approvals. MI heating cables are constructed and approved for use in non hazardous and hazardous (classified)areas. The maximum application temperature for heating units is 1022°F (550°C) and the maximum exposure temperature for the heating cable is 1238°F (670°C). Higher temperatures are available by special order.




 
 
 
Tyco Thermal Controls
Heat Tracing  
  

 
Home | Applications | Product Catalog | Documentation | Software / Design | FAQs / Tech. Support | Sales Representatives
 
 
 
 
 
 
 

 

 
  Not Logged In