Power-Limiting Heating Cables

 
 

Component and Accessory Selection for Self-Regulation and Power-Limiting Cables
Raychem ® brand power-limiting heating cables (VPL) feature high power output at high maintain temperatures. These flexible heating cables are rated for maintain temperatures up to 300°F (150°C) and exposure temperatures to 482°F (250°C). Power-limiting heating cables feature:

Superior temperature capability in a flexible heater
These cables are especially suited to applications requiring high power output at elevated temperatures and requiring field installation flexibility to accommodate small tank structure or design modifications.

Easy installation
Cables can be cut to length and terminated in the field.

Uniform distribution of heat
Heat is evenly and widely distributed over the heat-traced surface.

Approvals
Tyco Thermal Controls power-limiting systems are approved and certified for use in nonhazardous and hazardous locations by many agencies, including FM Approvals, CSA International, and Baseefa (2001) Ltd. Additional technical information can be found in the data sheet.

Description Catalog number
Components  
(1) Power connection kit (not shown) JBS-100-A
Power connection kit with light JBS-100-L-A
Splice connection (not shown) S-150 (not for use with VPL)
(2) End seal  
        Below insulation E-150 (not for use with VPL)
        Above insulation E-100-A
        Above insulation, with light E-100-L1-A, 100-120V
E-100-L2-A, 200-277 V
Accessories  
(3) Alumininum tape AT-180
(4) Labels ETL
(5) Support bracket SB-100-T
Controls  
(6) Thermostat (see Section 8, Control & Monitoring)  




Literature
Installation Operation and Maintenance Manuals
>>Industrial Installation & Maintenance Guide for Self Regulating and Power Limiting Heating Cables
Data Sheets
>>VPL Datasheet
Product Design and Selection Guides
>>Design Guide for Power Limiting Cables
Specifications
>>Engineering Specification for Electrical Heat-Tracing Systems (Word Format)
Miscellaneous
>>Product Safety Notice
Product Information
>>Industrial Heat Tracing Catalog

CONNECTION/TERMINATION KITS
End Seal Kits
E-100E-100-LE-150
Power Kits
JBM-100JBS-100JBS-100-ECP-A
Splice Kits
JBM-100S-150T-100
Tee Kits
JBM-100T-100 
CONTROL & MONITORING
Contactors
E104E304E307
Electronic Controllers
200NG200NI910
920JBS-100-ECP-AJBS-100-ECW-A
RAYSTAT-EX-03-AT2000 
Mechanical Thermostats
AMC-1AAMC-1BAMC-2B-2
AMC-F5 
HEAT TRACE PANELS
HTPGHTPI 
HEATING ACCESSORIES
Attachment Tapes, Cable Ties and Labels
AT-180GS-54GT-66
Mounting Brackets
JBM-SPAJBS-SPA 
Pipe Straps
PS-01,03,10,20

< back

   

Raychem
VPL

 VPL
Power-Limiting Cables are used for applications requiring high power output or exceed the temperature ranges of self-regulating cables. VPL can be used for freeze protection and process-temperature maintenance requiring high power output and/or high temperature exposure.

VPL can provide process-temperature maintenance up to 455°F (235°C) and can withstand routine steam purges and temperature excursions to 500°F (260°C) with power off. VPL cables are approved for use in non hazardous and hazardous locations.



 
 
 
Tyco Thermal Controls
Heat Tracing

 
Search
Home | Applications | Product Catalog | Documentation | Software / Design | FAQs / Tech. Support | Sales Representatives
We manage the heat you need.
 
 
 
 
 
 
 

 

 
  Not Logged In